AS ONE Corporation

Gas Detector Tube Dichloromethane

Gas Detector Tube Dichloromethane

AS ONE Corporation
&bull; Detecting tube name: 138 Dichloromethane<br> &bull; Number of measurements of 1 box: 5<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Dichloromethane <br> &bull; ?Measurement range: 20 - 500ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Ethyl chloride <br> &bull; ?Measurement range: 15 - 150ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Nitrogen Oxide

Gas Detector Tube Nitrogen Oxide

AS ONE Corporation
&bull; Detecting tube name: 10 Nitrogen oxide<br> &bull; Number of measurements of 1 box: 5<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Nitric oxide <br> &bull; ?Measurement range: 2.5 - 200ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Nitrogen oxide (for separation quantitative analysis) <br> &bull; ?Measurement range: 2.5 - 200ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: NO, NO2 for separation quantitative analysis
$0
Gas Detector Tube Trichloroethylene

Gas Detector Tube Trichloroethylene

AS ONE Corporation
&bull; Detecting tube name: 132L Trichloroethylene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 2 (refrigeration required)<br> &bull; <br> &bull; Measurement gas name: Trichloroethylene <br> &bull; ?Measurement range: 1 - 70ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Work environment measurement standards, drainage test<br> &bull; <br> &bull; Measurement gas name: Benzyl chloride <br> &bull; ?Measurement range: 1.6 - 20ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Trichloroethylene

Gas Detector Tube Trichloroethylene

AS ONE Corporation
&bull; Detecting tube name: 132LL trichloroethylene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 2 (refrigeration required)<br> &bull; <br> &bull; Measurement gas name: 1,2-Dichloroethylene <br> &bull; ?Measurement range: 0.375 - 6ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used, Working environment measurement standard<br> &bull; <br> &bull; Measurement gas name: Dichlorvos <br> &bull; ?Measurement range: 0.11 - 1.8ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Trichloroethylene <br> &bull; ?Measurement range: 0.125 - 8.8ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Work environment measurement standards, drainage test
$0
Gas Detector Tube Toluene

Gas Detector Tube Toluene

AS ONE Corporation
&bull; Detecting tube name: 122 Toluene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ethylbenzene <br> &bull; ?Measurement range: 11 - 330ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Toluene <br> &bull; ?Measurement range: 5 - 690ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -
$0
Gas Detector Tube Toluene

Gas Detector Tube Toluene

AS ONE Corporation
&bull; Detecting tube name: 122L toluene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ethylbenzene <br> &bull; ?Measurement range: 1 - 70ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Xylene <br> &bull; ?Measurement range: 2 - 200ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Cumene <br> &bull; ?Measurement range: 2 - 100ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Diethylbenzene <br> &bull; ?Measurement range: 2 - 150ppm <br> &bull; ?Standard suction times (n): 4 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Toluene <br> &bull; ?Measurement range: 1 - 100ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Working environment measurement standard
$0
Gas Detector Tube Hydrogen Fluoride

Gas Detector Tube Hydrogen Fluoride

AS ONE Corporation
&bull; Detecting tube name: 17 hydrogen fluoride<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Hydrogen fluoride <br> &bull; ?Measurement range: 0.25 - 100ppm <br> &bull; ?Standard suction times (n): 4 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Fluorine <br> &bull; ?Measurement range: 0.5 - 50ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Formaldehyde

Gas Detector Tube Formaldehyde

AS ONE Corporation
&bull; Detecting tube name: 91L formaldehyde<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3 (Refrigeration required)<br> &bull; <br> &bull; Measurement gas name: Diisobutyl ketone <br> &bull; ?Measurement range: 0.58 - 29ppm <br> &bull; ?Standard suction times (n): 4 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Cyclohexanone <br> &bull; ?Measurement range: 10 - 470ppm <br> &bull; ?Standard suction times (n): 10 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Propionaldehyde <br> &bull; ?Measurement range: 0.76 - 38ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Benzaldehyde <br> &bull; ?Measurement range: 4 - 92ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Formaldehyde <br> &bull; ?Measurement range: 0.1 - 40.0ppm <br> &bull; ?Standard suction times (n): 5 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Metaldehyde <br> &bull; ?Measurement range: 0.065 - 3.25ppm <br> &bull; ?Standard suction times (n): 3 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Methanol

Gas Detector Tube Methanol

AS ONE Corporation
&bull; Detecting tube name: 111L methanol<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ethylene chlorohydrin <br> &bull; ?Measurement range: 80 - 200ppm <br> &bull; ?Standard suction times (n): 3 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Methanol <br> &bull; ?Measurement range: 20 - 1000ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -
$0