AS ONE Corporation
Gas Detector Tube Dichloromethane
AS ONE Corporation
• Detecting tube name: 138 Dichloromethane<br>
• Number of measurements of 1 box: 5<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Dichloromethane <br>
• ?Measurement range: 20 - 500ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -<br>
• <br>
• Measurement gas name: Ethyl chloride <br>
• ?Measurement range: 15 - 150ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used
$0
Gas Detector Tube Nitrogen Oxide
AS ONE Corporation
• Detecting tube name: 11L Nitrogen oxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Nitrogen oxide <br>
• ?Measurement range: 0.04 - 16.5ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Nitrogen Oxide
AS ONE Corporation
• Detecting tube name: 10 Nitrogen oxide<br>
• Number of measurements of 1 box: 5<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Nitric oxide <br>
• ?Measurement range: 2.5 - 200ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -<br>
• <br>
• Measurement gas name: Nitrogen oxide (for separation quantitative analysis) <br>
• ?Measurement range: 2.5 - 200ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: NO, NO2 for separation quantitative analysis
$0
Gas Detector Tube Trichloroethylene
AS ONE Corporation
• Detecting tube name: 132M, trichloroethylene<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 2 (refrigeration required)<br>
• <br>
• Measurement gas name: Trichloroethylene <br>
• ?Measurement range: 2 - 250ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Drainage test
$0
Gas Detector Tube Trichloroethylene
AS ONE Corporation
• Detecting tube name: 132L Trichloroethylene<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 2 (refrigeration required)<br>
• <br>
• Measurement gas name: Trichloroethylene <br>
• ?Measurement range: 1 - 70ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Work environment measurement standards, drainage test<br>
• <br>
• Measurement gas name: Benzyl chloride <br>
• ?Measurement range: 1.6 - 20ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used
$0
Gas Detector Tube Trichloroethylene
AS ONE Corporation
• Detecting tube name: 132LL trichloroethylene<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 2 (refrigeration required)<br>
• <br>
• Measurement gas name: 1,2-Dichloroethylene <br>
• ?Measurement range: 0.375 - 6ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used, Working environment measurement standard<br>
• <br>
• Measurement gas name: Dichlorvos <br>
• ?Measurement range: 0.11 - 1.8ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used<br>
• <br>
• Measurement gas name: Trichloroethylene <br>
• ?Measurement range: 0.125 - 8.8ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Work environment measurement standards, drainage test
$0
Gas Detector Tube Toluene
AS ONE Corporation
• Detecting tube name: 122 Toluene<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Ethylbenzene <br>
• ?Measurement range: 11 - 330ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used<br>
• <br>
• Measurement gas name: Toluene <br>
• ?Measurement range: 5 - 690ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Toluene
AS ONE Corporation
• Detecting tube name: 122L toluene<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Ethylbenzene <br>
• ?Measurement range: 1 - 70ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Xylene <br>
• ?Measurement range: 2 - 200ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used<br>
• <br>
• Measurement gas name: Cumene <br>
• ?Measurement range: 2 - 100ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Diethylbenzene <br>
• ?Measurement range: 2 - 150ppm <br>
• ?Standard suction times (n): 4 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Toluene <br>
• ?Measurement range: 1 - 100ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Working environment measurement standard
$0
Gas Detector Tube Sulfur Dioxide
AS ONE Corporation
• Detecting tube name: 5Lb sulfur dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Sulfur dioxide <br>
• ?Measurement range: 0.05 - 10.0ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 2HH carbon dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Carbon dioxide <br>
• ?Measurement range: 2.5 - 40% <br>
• ?Standard suction times (n): 10 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 2H carbon dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Carbon dioxide <br>
• ?Measurement range: 0.5 - 20% <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 2L carbon dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Carbon dioxide <br>
• ?Measurement range: 0.13 - 6.0% <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 2LL carbon dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Carbon dioxide <br>
• ?Measurement range: 300 - 5000ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Building administration law
$0
Gas Detector Tube Carbon Dioxide
AS ONE Corporation
• Detecting tube name: 2LC carbon dioxide<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 2<br>
• <br>
• Measurement gas name: Carbon dioxide <br>
• ?Measurement range: 100 - 4000ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Building administration law
$0
Gas Detector Tube Carbon Disulfide
AS ONE Corporation
• Detecting tube name: 13 carbon disulfide<br>
• Number of measurements of 1 box: 5<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Carbon Disulfide <br>
• ?Measurement range: 0.63 - 100ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Hydrogen Fluoride
AS ONE Corporation
• Detecting tube name: 17 hydrogen fluoride<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Hydrogen fluoride <br>
• ?Measurement range: 0.25 - 100ppm <br>
• ?Standard suction times (n): 4 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -<br>
• <br>
• Measurement gas name: Fluorine <br>
• ?Measurement range: 0.5 - 50ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used
$0
Gas Detector Tube Formaldehyde
AS ONE Corporation
• Detecting tube name: 91 formaldehyde<br>
• Number of measurements of 1 box: 5<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Formaldehyde <br>
• ?Measurement range: 2 - 100ppm <br>
• ?Standard suction times (n): 2 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Formaldehyde
AS ONE Corporation
• Detecting tube name: 91L formaldehyde<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3 (Refrigeration required)<br>
• <br>
• Measurement gas name: Diisobutyl ketone <br>
• ?Measurement range: 0.58 - 29ppm <br>
• ?Standard suction times (n): 4 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used<br>
• <br>
• Measurement gas name: Cyclohexanone <br>
• ?Measurement range: 10 - 470ppm <br>
• ?Standard suction times (n): 10 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Propionaldehyde <br>
• ?Measurement range: 0.76 - 38ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used<br>
• <br>
• Measurement gas name: Benzaldehyde <br>
• ?Measurement range: 4 - 92ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Formaldehyde <br>
• ?Measurement range: 0.1 - 40.0ppm <br>
• ?Standard suction times (n): 5 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -<br>
• <br>
• Measurement gas name: Metaldehyde <br>
• ?Measurement range: 0.065 - 3.25ppm <br>
• ?Standard suction times (n): 3 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Conversion factor used
$0
Gas Detector Tube Formaldehyde
AS ONE Corporation
• Detecting tube name: 91LL formaldehyde<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 1 (refrigeration required)<br>
• <br>
• Measurement gas name: Formaldehyde <br>
• ?Measurement range: 0.05 - 1.0ppm <br>
• ?Standard suction times (n): 5 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0
Gas Detector Tube Methanol
AS ONE Corporation
• Detecting tube name: 111L methanol<br>
• Number of measurements of 1 box: 10<br>
• Expiration date (year): 3<br>
• <br>
• Measurement gas name: Ethylene chlorohydrin <br>
• ?Measurement range: 80 - 200ppm <br>
• ?Standard suction times (n): 3 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: Used conversion scale<br>
• <br>
• Measurement gas name: Methanol <br>
• ?Measurement range: 20 - 1000ppm <br>
• ?Standard suction times (n): 1 <br>
• ?Measurement time (hr): - <br>
• ?Special remarks: -
$0