Gas Detector Tube Toluene

&bull; Detecting tube name: 122 Toluene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ethylbenzene <br> &bull; ?Measurement range: 11 - 330ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Toluene <br> &bull; ?Measurement range: 5 - 690ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -

Cheapest shipping from $0
SKU: 9-801-58
MPN: 9-801-58
GTIN: NULL
Stock Status: 1,000 pcs
Delivery Status: 1-3 days
$0
pcs

Description

• Detecting tube name: 122 Toluene
• Number of measurements of 1 box: 10
• Expiration date (year): 3
•
• Measurement gas name: Ethylbenzene
• ?Measurement range: 11 - 330ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Toluene
• ?Measurement range: 5 - 690ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -

Similar Products

Gas Detector Tube Toluene

Gas Detector Tube Toluene

AS ONE Corporation
&bull; Detecting tube name: 122L toluene<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ethylbenzene <br> &bull; ?Measurement range: 1 - 70ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Xylene <br> &bull; ?Measurement range: 2 - 200ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Cumene <br> &bull; ?Measurement range: 2 - 100ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Diethylbenzene <br> &bull; ?Measurement range: 2 - 150ppm <br> &bull; ?Standard suction times (n): 4 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Used conversion scale<br> &bull; <br> &bull; Measurement gas name: Toluene <br> &bull; ?Measurement range: 1 - 100ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Working environment measurement standard
$0