Gas Detector Tube Formaldehyde
• Detecting tube name: 91L formaldehyde<br> • Number of measurements of 1 box: 10<br> • Expiration date (year): 3 (Refrigeration required)<br> • <br> • Measurement gas name: Diisobutyl ketone <br> • ?Measurement range: 0.58 - 29ppm <br> • ?Standard suction times (n): 4 <br> • ?Measurement time (hr): - <br> • ?Special remarks: Conversion factor used<br> • <br> • Measurement gas name: Cyclohexanone <br> • ?Measurement range: 10 - 470ppm <br> • ?Standard suction times (n): 10 <br> • ?Measurement time (hr): - <br> • ?Special remarks: Used conversion scale<br> • <br> • Measurement gas name: Propionaldehyde <br> • ?Measurement range: 0.76 - 38ppm <br> • ?Standard suction times (n): 1 <br> • ?Measurement time (hr): - <br> • ?Special remarks: Conversion factor used<br> • <br> • Measurement gas name: Benzaldehyde <br> • ?Measurement range: 4 - 92ppm <br> • ?Standard suction times (n): 1 <br> • ?Measurement time (hr): - <br> • ?Special remarks: Used conversion scale<br> • <br> • Measurement gas name: Formaldehyde <br> • ?Measurement range: 0.1 - 40.0ppm <br> • ?Standard suction times (n): 5 <br> • ?Measurement time (hr): - <br> • ?Special remarks: -<br> • <br> • Measurement gas name: Metaldehyde <br> • ?Measurement range: 0.065 - 3.25ppm <br> • ?Standard suction times (n): 3 <br> • ?Measurement time (hr): - <br> • ?Special remarks: Conversion factor used
Description
• Number of measurements of 1 box: 10
• Expiration date (year): 3 (Refrigeration required)
•
• Measurement gas name: Diisobutyl ketone
• ?Measurement range: 0.58 - 29ppm
• ?Standard suction times (n): 4
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Cyclohexanone
• ?Measurement range: 10 - 470ppm
• ?Standard suction times (n): 10
• ?Measurement time (hr): -
• ?Special remarks: Used conversion scale
•
• Measurement gas name: Propionaldehyde
• ?Measurement range: 0.76 - 38ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Benzaldehyde
• ?Measurement range: 4 - 92ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Used conversion scale
•
• Measurement gas name: Formaldehyde
• ?Measurement range: 0.1 - 40.0ppm
• ?Standard suction times (n): 5
• ?Measurement time (hr): -
• ?Special remarks: -
•
• Measurement gas name: Metaldehyde
• ?Measurement range: 0.065 - 3.25ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used