AS ONE Corporation

Gas Detector Tube Ammonia

Gas Detector Tube Ammonia

AS ONE Corporation
&bull; Detecting tube name: 3M Ammonia<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Ammonia <br> &bull; ?Measurement range: 10 - 1000ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Trimethylamine <br> &bull; ?Measurement range: 25 - 250ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Ethylene Oxide

Gas Detector Tube Ethylene Oxide

AS ONE Corporation
&bull; Detecting tube name: 163L Ethylene oxide<br> &bull; Number of measurements of 1 box: 5<br> &bull; Expiration date (year): 1 (refrigeration required)<br> &bull; <br> &bull; Measurement gas name: Ethylene oxide <br> &bull; ?Measurement range: 0.4 - 350ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Epichlorohydrin <br> &bull; ?Measurement range: 1.2 - 120ppm <br> &bull; ?Standard suction times (n): 2 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Propylene oxide <br> &bull; ?Measurement range: 1 - 100ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Chlorine

Gas Detector Tube Chlorine

AS ONE Corporation
&bull; Detecting tube name: 8La chlorine<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Chlorine <br> &bull; ?Measurement range: 0.1 - 16ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Bromine <br> &bull; ?Measurement range: 0.05 - 0.8ppm <br> &bull; ?Standard suction times (n): 4 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Chlorine dioxide <br> &bull; ?Measurement range: 0.3 - 4.8ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Acetic Acid

Gas Detector Tube Acetic Acid

AS ONE Corporation
&bull; Detecting tube name: 81 Acetic acid<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 3<br> &bull; <br> &bull; Measurement gas name: Acrylic Acid (stabilized with MEHQ) <br> &bull; ?Measurement range: 2 - 50ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Isovaleric Acid <br> &bull; ?Measurement range: 2 - 50ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Formic acid <br> &bull; ?Measurement range: 5.2 - 130ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Propionic Acid <br> &bull; ?Measurement range: 3 - 75ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Methacrylic Acid (stabilized with MEHQ) <br> &bull; ?Measurement range: 1.8 - 45ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Acetic acid <br> &bull; ?Measurement range: 1 - 100ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Maleic Anhydride <br> &bull; ?Measurement range: 0.8 - 20ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Acetic anhydride <br> &bull; ?Measurement range: 0.6 - 15ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0
Gas Detector Tube Acetic Acid

Gas Detector Tube Acetic Acid

AS ONE Corporation
&bull; Detecting tube name: 81L acetic acid<br> &bull; Number of measurements of 1 box: 10<br> &bull; Expiration date (year): 2 (refrigeration required)<br> &bull; <br> &bull; Measurement gas name: Acrylic Acid (stabilized with MEHQ) <br> &bull; ?Measurement range: 0.45 - 18ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Isovaleric Acid <br> &bull; ?Measurement range: 0.38 - 15ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Formic acid <br> &bull; ?Measurement range: 0.5 - 20ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Propionic Acid <br> &bull; ?Measurement range: 0.25 - 10ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Methacrylic Acid (stabilized with MEHQ) <br> &bull; ?Measurement range: 0.35 - 14ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Valeric Acid <br> &bull; ?Measurement range: 0.38 - 15ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Acetic acid <br> &bull; ?Measurement range: 0.125 - 25.0ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -<br> &bull; <br> &bull; Measurement gas name: Acetic anhydride <br> &bull; ?Measurement range: 0.15 - 6ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Butyric Acid <br> &bull; ?Measurement range: 0.325 - 13ppm <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used
$0