High Speed Shaker
<br> • Model number: ASCM-1<br> • Rotation speed: 300 - 1800rpm<br> • Shaking speed: When tube rack for 0.5mL, for 1.5mL is installed/300 - 1800rpm, When laboratory centrifuge rack for 50mL is installed/300 - 1500rpm, When laboratory centrifuge rack for 15mL is installed/300 - 1800rpm, When rack for microplate is installed/300 - 1200rpm, When rack for vortex is installed/300 - 2500rpm<br> • Power supply: 100VAC 50/60Hz<br> • Shaking method: Turning<br> • Rotation amplitude: 3mm<br> • Timer function: 30 minutes<br> • Weight: Approx 4.5kg<br> • Size: 150 x 157 x 133mm<br> • Cute mixer<br> • *Rack is not included in the package. *Shaken speed range varies the rack to attach. <br> • It is possible to use it by a wide usage like the extraction of DNA and RNA and dissolution, the mixture, and the ELISA experiment etc. of the reagent. vSeven kinds of shake for 0.5-1.5*ml* micro tubes, for 15-50*ml*, for centrifugation pipes, for deepwell, for vortexes and for microplates are possible by using various racks properly. <br> • Attachment and detachment of a rack are possible at one-touch. <br> • Any type of a rack has the structure where a churning state can be checked. vThe timer for 30 minutes is equipped normally. The range of the stir was displayed in the control panel according to the rack.
Description
• Model number: ASCM-1
• Rotation speed: 300 - 1800rpm
• Shaking speed: When tube rack for 0.5mL, for 1.5mL is installed/300 - 1800rpm, When laboratory centrifuge rack for 50mL is installed/300 - 1500rpm, When laboratory centrifuge rack for 15mL is installed/300 - 1800rpm, When rack for microplate is installed/300 - 1200rpm, When rack for vortex is installed/300 - 2500rpm
• Power supply: 100VAC 50/60Hz
• Shaking method: Turning
• Rotation amplitude: 3mm
• Timer function: 30 minutes
• Weight: Approx 4.5kg
• Size: 150 x 157 x 133mm
• Cute mixer
• *Rack is not included in the package. *Shaken speed range varies the rack to attach.
• It is possible to use it by a wide usage like the extraction of DNA and RNA and dissolution, the mixture, and the ELISA experiment etc. of the reagent. vSeven kinds of shake for 0.5-1.5*ml* micro tubes, for 15-50*ml*, for centrifugation pipes, for deepwell, for vortexes and for microplates are possible by using various racks properly.
• Attachment and detachment of a rack are possible at one-touch.
• Any type of a rack has the structure where a churning state can be checked. vThe timer for 30 minutes is equipped normally. The range of the stir was displayed in the control panel according to the rack.