Gas Detector Tube Lower Hydrocarbon

&bull; Detecting tube name: 103 Lower hydrocarbon<br> &bull; Number of measurements of 1 box: 9<br> &bull; Expiration date (year): 2<br> &bull; <br> &bull; Measurement gas name: Acetylene <br> &bull; ?Measurement range: 0.075 - 3.6% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Isobutane <br> &bull; ?Measurement range: 0.035 - 1.68% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Isopentane <br> &bull; ?Measurement range: 0.045 - 2.16% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Ethylene <br> &bull; ?Measurement range: 0.35 - 16.8% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Butane <br> &bull; ?Measurement range: 0.035 - 1.68% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Propane <br> &bull; ?Measurement range: 0.05 - 2.4% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Hexane <br> &bull; ?Measurement range: 0.025 - 1.2% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Heptane <br> &bull; ?Measurement range: 0.035 - 1.68% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Pentane <br> &bull; ?Measurement range: 0.0375 - 1.8% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: Conversion factor used<br> &bull; <br> &bull; Measurement gas name: Lower hydrocarbon <br> &bull; ?Measurement range: 0.05 - 2.4% <br> &bull; ?Standard suction times (n): 1 <br> &bull; ?Measurement time (hr): - <br> &bull; ?Special remarks: -

Cheapest shipping from $0
SKU: 9-801-43
MPN: 9-801-43
GTIN: NULL
Stock Status: 1,000 pcs
Delivery Status: 1-3 days
$0
pcs

Description

• Detecting tube name: 103 Lower hydrocarbon
• Number of measurements of 1 box: 9
• Expiration date (year): 2
•
• Measurement gas name: Acetylene
• ?Measurement range: 0.075 - 3.6%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Isobutane
• ?Measurement range: 0.035 - 1.68%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Isopentane
• ?Measurement range: 0.045 - 2.16%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Ethylene
• ?Measurement range: 0.35 - 16.8%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Butane
• ?Measurement range: 0.035 - 1.68%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Propane
• ?Measurement range: 0.05 - 2.4%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Hexane
• ?Measurement range: 0.025 - 1.2%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Heptane
• ?Measurement range: 0.035 - 1.68%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Pentane
• ?Measurement range: 0.0375 - 1.8%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used
•
• Measurement gas name: Lower hydrocarbon
• ?Measurement range: 0.05 - 2.4%
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -

Similar Products