AS ONE Corporation
[Global Model]Steam Sterilizer (Laboratory Use, Large Capacity) SQ510
AS ONE Corporation
• System: Automatic high-pressure steam sterilization for lab
• Operating temperature range: 45~135? 45~80?(Preheating temperature)/45~60?(Heat-retention process)/65~100?(Solution process)/105~135?(Sterilization)
• Max. working pre
• Operating temperature range: 45~135? 45~80?(Preheating temperature)/45~60?(Heat-retention process)/65~100?(Solution process)/105~135?(Sterilization)
• Max. working pre
$0
[Global Model]Spray Dryer (Large Capacity) DL410
AS ONE Corporation
• Water evaporation rate Max. approx. 3,000 ml/h
• Spraying system: Two-way nozzle (Dia. of orifice: 0.7mm) Nozzle No.3 standard supply
• Spray/hot air contact system: Downward spray parallel flow system
• Sample liquid f
• Spraying system: Two-way nozzle (Dia. of orifice: 0.7mm) Nozzle No.3 standard supply
• Spray/hot air contact system: Downward spray parallel flow system
• Sample liquid f
$0
[Global Model]Clean Oven DE411
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.3? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.5?(a
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.3? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.5?(a
$0
[Global Model]Clean Oven DE611
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.3? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.5?(a
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.3? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.5?(a
$0
[Global Model]Clean Oven DT411
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.3? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?4.0?(a
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.3? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?4.0?(a
$0
[Global Model]Clean Oven DT611
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.3? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?4.0?(a
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.3? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?4.0?(a
$0
[Global Model]Clean Oven (Large Capacity) DES830
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.5? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.0?(a
• Operating temp. range: RT+30~260?
• Temp. adjustment accuracy: ?0.5? (at 260?) JTM K05
• Temp. fluctuation: 1.0?(at 260?) JIS
• Temp. distribution accuracy: ?2.0?(a
$0
[Global Model]Clean Oven (High Temp. & Large Capacity) DTS830
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.5? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?5.0?(a
• Operating temp. range: RT+30~360?
• Temp. adjustment accuracy: ?0.5? (at 360?) JTM K05
• Temp. fluctuation: 1.0?(at 360?) JIS
• Temp. distribution accuracy: ?5.0?(a
$0
[Global Model]Fine Oven (Large Capacity) DF832
AS ONE Corporation
• Circulation method: Forced convection and ventilation
• Operating temp. range: (Forced convection) RT+15~200?
• Temp. fluctation: 3? (at 200?)
• Temp. gradient: 12? (at 200?)
• Internal dimentions(WxDxH): 80
• Operating temp. range: (Forced convection) RT+15~200?
• Temp. fluctation: 3? (at 200?)
• Temp. gradient: 12? (at 200?)
• Internal dimentions(WxDxH): 80
$0
[Global Model]Fine Oven (Large Capacity) DF1032
AS ONE Corporation
• Circulation method: Forced convection and ventilation
• Operating temp. range: (Forced convection) RT+15~200?
• Temp. fluctation: 3? (at 200?)
• Temp. gradient: 12? (at 200?)
• Internal dimentions(WxDxH): 10
• Operating temp. range: (Forced convection) RT+15~200?
• Temp. fluctation: 3? (at 200?)
• Temp. gradient: 12? (at 200?)
• Internal dimentions(WxDxH): 10
$0
[Global Model]Fine Oven (High Temp. & Large Capacity) DH832
AS ONE Corporation
• Circulation method: Forced convection and ventilation
• Operating temp. range: (Forced convection) RT+15~300?
• Temp. fluctation: 3? (at 300?)
• Temp. gradient: 18? (at 300?)
• Internal dimentions(WxDxH): 80
• Operating temp. range: (Forced convection) RT+15~300?
• Temp. fluctation: 3? (at 300?)
• Temp. gradient: 18? (at 300?)
• Internal dimentions(WxDxH): 80
$0
[Global Model]Fine Oven (High Temp. & Large Capacity) DH1032
AS ONE Corporation
• Circulation method: Forced convection and ventilation
• Operating temp. range: (Forced convection) RT+15~300?
• Temp. fluctation: 3? (at 300?)
• Temp. gradient: 18? (at 300?)
• Internal dimentions(WxDxH): 10
• Operating temp. range: (Forced convection) RT+15~300?
• Temp. fluctation: 3? (at 300?)
• Temp. gradient: 18? (at 300?)
• Internal dimentions(WxDxH): 10
$0
[Global Model]Fine Oven (Tall) DFS710
AS ONE Corporation
• Circulation method: Forced air circulation and ventilation
• Operating temp. range: RT+15~260?
• Max. temp. reaching time: Approx. 40 min (at 260?)
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. di
• Operating temp. range: RT+15~260?
• Max. temp. reaching time: Approx. 40 min (at 260?)
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. di
$0
[Global Model]Fine Oven (Tall) DFS810
AS ONE Corporation
• Circulation method: Forced air circulation and ventilation
• Operating temp. range: RT+15~260?
• Max. temp. reaching time: Approx. 40 min (at 260?)
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. di
• Operating temp. range: RT+15~260?
• Max. temp. reaching time: Approx. 40 min (at 260?)
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. di
$0
[Global Model]Fine Oven (Tall) DHS710
AS ONE Corporation
• Circulation method: Forced air circulation and ventilation
• Operating temp. range: RT+15~360?
• Max. temp. reaching time: Approx. 50 min (at 360?)
• Temp. adjustment accuracy: ?0.3?(at360?) JTM K05
• Temp. di
• Operating temp. range: RT+15~360?
• Max. temp. reaching time: Approx. 50 min (at 360?)
• Temp. adjustment accuracy: ?0.3?(at360?) JTM K05
• Temp. di
$0
[Global Model]Fine Oven (Tall) DHS810
AS ONE Corporation
• Circulation method: Forced air circulation and ventilation
• Operating temp. range: RT+15~360?
• Max. temp. reaching time: Approx. 50 min (at 360?)
• Temp. adjustment accuracy: ?0.3?(at360?) JTM K05
• Temp. di
• Operating temp. range: RT+15~360?
• Max. temp. reaching time: Approx. 50 min (at 360?)
• Temp. adjustment accuracy: ?0.3?(at360?) JTM K05
• Temp. di
$0
[Global Model]Vacuum Drying Oven DP410
AS ONE Corporation
• System: Vacuum drying by decompressed chamber direct heating
• Operating temp. range: 40~200?
• Operating pressure range: 101~0.1kPa (760~1 Torr)
• Temp. control accuracy: ?1.0?(at 200?) JTM K05
• Temp. fluctu
• Operating temp. range: 40~200?
• Operating pressure range: 101~0.1kPa (760~1 Torr)
• Temp. control accuracy: ?1.0?(at 200?) JTM K05
• Temp. fluctu
$0
[Global Model]Vacuum Drying Oven DP610
AS ONE Corporation
• System: Vacuum drying by decompressed chamber direct heating
• Operating temp. range: 40~200?
• Operating pressure range: 101~0.1kPa (760~1 Torr)
• Temp. control accuracy: ?1.0?(at 200?) JTM K05
• Temp. fluctu
• Operating temp. range: 40~200?
• Operating pressure range: 101~0.1kPa (760~1 Torr)
• Temp. control accuracy: ?1.0?(at 200?) JTM K05
• Temp. fluctu
$0
[Global Model]Forced Convection Oven (Energy Saving) DNE670
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
$0
[Global Model]Forced Convection Oven (Energy Saving) DNE850
AS ONE Corporation
• Circulation method: Forced air circulation
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
• Operating temp. range: RT+10~260?
• Temp. adjustment accuracy: ?0.2?(at260?) JTM K05
• Temp. distribution accuracy: ?2.0?(at260?)JTM K05
• Max. temp. reaching time:
$0