Gas Detector Tube Amines

$0.00

  • Model:9-800-11
Product may vary slightly from image representation.
• Detecting tube name: 180. Amines
• Number of measurements of 1 box: 10
• Expiration date (year): 3

• Measurement gas name: N,N-Diethylethanolamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: N,N-Dimethylethylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: N.N-Dimethylethanolamine
• ?Measurement range: 6.5 - 130ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: N-Ethylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: n- Butylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: N-Methylmorpholine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: tert-Butylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Amines
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: -

• Measurement gas name: Ammonia
• ?Measurement range: 1.5 - 30ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Isopropylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Ethanolamine (monoethanolamine)
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 3
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Ethylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Ethylenediamine
• ?Measurement range: 14 - 280ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Di -n- Butylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Diisopropylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Diethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Cyclohexylamine
• ?Measurement range: 7 - 140ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Dipropylamine
• ?Measurement range: 4 - 80ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Dimethylaminopropylamine
• ?Measurement range: 8 - 160ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Dimethylamine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Tetramethylenediamine
• ?Measurement range: 8.5 - 170ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Triethylamine
• ?Measurement range: 4.5 - 90ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Trimethylamine
• ?Measurement range: 3.5 - 70ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Propylamine
• ?Measurement range: 6 - 120ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Hexylamine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Methylamine
• ?Measurement range: 5 - 100ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Morpholine
• ?Measurement range: 9 - 180ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used

• Measurement gas name: Propylenimine
• ?Measurement range: 5.5 - 110ppm
• ?Standard suction times (n): 1
• ?Measurement time (hr): -
• ?Special remarks: Conversion factor used